Hi-2621 pH and Orp Benchtop Meter with Data Logging
The HI-2621 benchtop meter is a fast, accurate pH and ORP meter with probes for pH and Orp. The sensors measure the parameter together with the temperature.
Simply and easy to use : Configuration, calibration, measurement and data logging.
Useful for routine applications together with a Standard Operating Mode, enabling all features and capabilities.
The HI-2621 meter has a large display - 5.5” (14 cm) LCD.
Main feature points
- Automatic parameter recognition
- pH/ORP choice of measurement units: pH, mV;
- CAL Check indicators
- Sensor Check indicators
- Basic mode for simplified operation
- Dedicated GLP key
- GLP data included with logged data
- Simplified data transfer to a PC
- Internal clock and date
Key Features
- Digital probe input
- Two operating modes - Standard or Basic Operating Modes (pH and EC only). Standard Mode enables all features while Basic Mode displays a simplified screen and features
- Data storage up to 1000 log records.
- GLP - The sensor retains data from the most recent calibration, including date, time, and buffers utilised.
- CAL Check - CAL Check feature analyses the pH electrode’s response in calibration buffers to detect potential issues such as contaminated solutions or dirty electrodes.
- ORP measurement - Measure ORP (REDOX) in mV units by using a compatible ORP sensor.
| Specifications of the HIO2621 | |
|---|---|
| pH - using HI-11310 Electrode pH | |
| _____ | |
| pH Range | basic mode: -2.00 to 16.00 pH; standard mode: -2.000 to 16.000 pH |
| Resolution | basic mode: 0.01 pH; standard mode: 0.001 pH |
| Accuracy | basic mode: ±0.01 pH; standard mode: ±0.002 pH |
| Calibration | Basic Mode: Automatic, up to three points, option to select 5 standard buffers |
| Standard mode: Automatic, up to five point calibration, 7 standard buffers available and two custom buffers. | |
| Temperature Compensation | Automatic, -5.0 to 100.0°C (using integral temperature sensor) |
| Logging | Up to 1000 (in Standard Mode) records organised in: |
| Manual log-on-demand, maximum 200 logs | |
| Manual log-on-stability, maximum 200 logs | |
| Interval logging in Standard Mode | |
| ________ | |
| mV - using HI-11310 pH electrode | |
| _____ | |
| mV pH Range | ±1000 mV |
| Resolution | 0.1 mV |
| Accuracy at 25°C | ±0.2 mV |
| __________ | |
| ORP – using HI-36180 ORP electrode | |
| _____ | |
| Orp Range | ±2000.0 mV |
| Resolution | 0.1 mV |
| Accuracy at 25°C | ±0.2 mV (±999.9mV); ±1mV (±2000mV) |
| Calibration | Single point offset |
| Temperature Compensation | Automatic, using integral temperature sensor -5.0 to 100.0°C |
| Logging | Up to 1000 in Standard Mode records organised in: |
| Manual log-on-demand, maximum 200 logs | |
| Manual log-on-stability, maximum 200 logs | |
| Interval logging in Standard Mode | |
| Temperature Range | -20.0 to 120.0 °C (temp limits reduced to probe limits) |
| Resolution | 0.1°C |
| Accuracy | ±0.5°C |