VC-220 Vibration Comparator

Monitor production facilities - check vibration & sound

The VC-2200/3200 is a Vibration comparator which is used for maintenance and constant monitoring of production facilities with high accuracy, high function, and low cost in a single unit.


The VC-2200/3200 Vibration Comparator utilises high-speed calculation by employing a digital signal processor (DSP) in DIN size. Newly installed TEDS function enables high performance calculation, time reduction, and less human errors in setup.


From the output signal of an accelerometer, the VC-2200/3200 simultaneously records two different frequencies with one unit. Data is easily managed with a PC. The VC-2200/3200 has multiple roles including detection, judgment, and data management.


The VC-2200/3200 features checking of "visual and auditory". It has function of checking vibration with sound by connecting headphones together with checking the vibration on-screen via numerical displays and bar graphs.


The "comparator gate input function" can extract vibration phenomenon by controlling the timing signals from a PLC. All of these functions are packed into a compact DIN size (96mm X 96mm).


Features:

  • Simultaneous two-band measurement
  • Digital display function
  • Analog output
  • Headphone output
  • Comparator gate
  • Comparator time delay setting
  • Compact 96 x 96 (DIN) size.


VC 220 Vibration Comparator
Specifications
No. of input channels 1
Number of settable bands 2
Measurement mode Rms, Peak, Maximum hold, Peak hold
Sensor sensitivity set up 1.00 x10-2 to 9.99 x102 mV/(m/s2)digital input
Input range 0.1 to 50,000 m/s2 (Setup range differs depending on the sensor sensitivity.) (example : The input range will be 2.000 to 1000 m/s2 when a sensor with 5 mV/(m/s2) sensitivity is used. )
Frequency characteristics 3 Hz to 15 kHz ±0.5 dB 1.5 Hz to 20 kHz ±3 dB (160 Hz reference value)
Input reference noise 3 Hz to 20 kHz band: 30 µVrms or less
Dynamic Range Through /AC : 80 dB or more(input voltage range x1, x2, x5) 70 dB or more(input voltage range x10, x20, x50, x100, x200, x500) THR(Through) : 1.5 Hz to 40 kHz bands AC : 1.5 Hz to 20 kHz bands
TEDS function Available to the TEDS sensor (IEEE1451.4)(Ver1.0 or later)
Current Consumption 0.2 A or less (25 °C)
Power Supply Rated DC24 V (±10 %)
Storage Temperature −5 to + 55 °C
Operating Temperature 0 to + 50 °C

Wide Range of Features

Logarithmic bar chart


Easily viewable small level vibration

Headphone volume MUTE function 


Mute function protects ears from impulsive sound when a sensor is mounted

Settings of measurement/judging conditions by one command 


Measurement conditions or judging conditions can be set by one command. Selectable from setting in a batch or each setting